AS-Interface Master – Modbus Plus Slave

£860.00

The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very easy using the windows based configuration software Anybus Configuration Manager X-gateway from HMS (free of charge).

SKU: AB7829

Product Description

The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very easy using the windows based configuration software Anybus Configuration Manager X-gateway from HMS (free of charge).

The AS-Interface Master for the Anybus X-gateway implements an extended AS-Interface master (M4), and complies to version 3.0 of the AS-I Complete Specification.
It supports up to 62 slaves with a maximum of 248 digital input and 186 output signals. It also supports 124 analog values. All standard services are available including detailed diagnostics. The network interface is optically isolated and equipped with a 2-pin pluggable screw connector. The Master supports intelligent auto-configuration via the on-board configuration button or manual configuration via a terminal program such as Hyper Terminal for Windows.
The AS-interface module is certified by the AS Interface user organization and has proven conformance and interoperability with leading manufacturers of I/O, sensors, valves etc.

The Modbus Plus interface is based on licensed chip-set and software from Modicon Inc. Supporting both the Global Database and Register mapping to 3x and 4x registers this module implements a versatile Modbus Plus interface. The Modbus Plus interface module is certified by the Modconnect and has proven conformance and interoperability with leading PLC´s, HMI´s etc

 

 

Manages control of up to 62 AS-Interface slaves
248 digital inputs and 186 digital outputs
Intelligent auto configuration support
Modbus Plus Global Data Base Transaction, Point-to-Point commands, Read holding registers, Preset single register
Modbus Plus Host Firmware Rev. 77
Supporting AS-Interface version 3.0

Size: 114 mm x 44 mm x 127 mm

Power Supply: 24 VDC (±20%)

Temperature: -25-65°C

Current Consump: max 400 mA

I/O Input: Default 20 bytes, max 64 bytes (248 digital inputs on ASI)

I/O Output: Default 20 bytes, max 64 bytes (186 digital outputs on ASI)

Mech Rating: IP20/Nema1

Power supply connector: 2-pole 5.08 mm Phoenix pluggable screw connector

AS-I baudrate: 167 kbit/s

AS-I connector: 2 x 2-pole 5.08 mm Phoenix pluggable screw connectors

Modbus Plus baudrate: 1 Mbit/s

Modbus Plus address: Node-ID and Source-ID 1-64

ModbusPlus connector: D-sub 9-pin female

Price Group: C

Order Code: AB7829

 