DeviceNet Adapter/Slave – CANopen Slave

£430.00

The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very easy using the windows based configuration software Anybus Configuration Manager X-gateway from HMS (free of charge).

 

SKU: AB7859

Product Description

The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very easy using the windows based configuration software Anybus Configuration Manager X-gateway from HMS (free of charge).

The high performance DeviceNet Slave interface provides instant connectivity to the DeviceNet network. The module conforms to DeviceNet 2.0. The DeviceNet interface module is certified by the ODVA and has proven conformance and interoperability with leading PLC´s, HMI´s etc. Baud rate and MAC ID can be set via DIP switches.

The CANopen interface is an adapter class product allowing fast data exchange. The CANopen slave?s data map consists of Process Data Objects (fast data) and Service Data Objects (slow data). The data on the CANopen bus is updated when a change is made or on request from another node. The CANopen interface module is certified by the Can In Automation organisation and has proven conformance and interoperability with leading PLC´s, SoftPLC´s, HMI´s etc 

 

 

DeviceNet Specification version: Vol 1: 2.0, Vol 2: 2.0
Conformance test version: A-12
I/O Slave messaging: Bit strobe, Polling, Cyclic, COS and Explicit Messaging
CANopen PDO and SDO data objects supported
CANopen Unscheduled data exchange support
CANopen profile DS-301 v.4.02
Customizable PDO-mapping
Heatbeat and node guarding support
Network Stor/Restore functionality

Size: 114 mm x 44 mm x 127 mm

Power Supply: 24 VDC (±20%)

Temperature: -25-65°C

Current Consump: Max 400mA at 24VDC

I/O Input: Default 20 bytes, max 512 bytes

I/O Output: Default 20 bytes, max 512 bytes

Mech Rating: IP20/Nema1

Power supply connector: 2-pole 5.08 mm Phoenix pluggable screw connector

DeviceNet baud rate: 125-500 kbit/s

DeviceNet MacID: 0-63

DeviceNet connector: 5-pole 5.08 mm Phoenix pluggable screw connector

DeviceNet config.: Configured by DeviceNet Scanner via EDS file (provided by HMS)

CANopen baudrate: 10 kbit/s to 1 Mbit/s

CANopen connector: D-sub 9-pin male

CANopen address: Node address 1-99

CANopen config.: Configured by CanOpen Master via EDS file (provided by HMS)

Price Group: A

Order Code: AB7859

Reviews

There are no reviews yet.

Be the first to review “DeviceNet Adapter/Slave – CANopen Slave”

Your email address will not be published. Required fields are marked *