DeviceNet Scanner/Master – Modbus Plus Slave

£860.00

The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very easy using the windows based configuration software Anybus Configuration Manager X-gateway from HMS (free of charge).

SKU: AB7818

Product Description

The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very easy using the windows based configuration software Anybus Configuration Manager X-gateway from HMS (free of charge).

The DeviceNet Master interface can act both as a Master/Scanner and/or Adapter/Slave. The entire DeviceNet protocol is implemented into the module. The module manages control of up to 63 DeviceNet slaves. Full DeviceNet configuration can be defined and loaded into the Anybus-M module via the HMS configuration software NetTool-DN (included free of charge) or via Rockwell´s RSNetWorx. 

The Modbus Plus interface is based on licensed chip-set and software from Modicon Inc. Supporting both the Global Database and Register mapping to 3x and 4x registers this module implements a versatile Modbus Plus interface. The Modbus Plus interface module is certified by the Modconnect and has proven conformance and interoperability with leading PLC´s, HMI´s etc 

 

 

Complete DeviceNet 2.0 scanner implementation according to ODVA
DeviceNet Group 2 Client/Server / UCMM support
Manages up to 63 DeviceNet slaves
DeviceNet Configuration via AnyBus NetTool-DN or RSNetworx
DeviceNet Explicit peer to peer messaging, configuration consistency value. I/O Slave messaging: Bit strobe, Polling, Cyclic & Change of State (COS)
Modbus Plus Global Data Base Transaction, Point-to-Point commands, Read holding registers, Preset single register
Modbus Plus Host Firmware Rev. 77

Size: 114 mm x 44 mm x 127 mm

Power Supply: 24 VDC (±20%)

Temperature: -25-65°C

Current Consump: max 400 mA

I/O Input: Default 20 bytes, max 512 bytes (max 64 bytes as Modbus Plus Global Data)

I/O Output: Default 20 bytes, max 512 bytes (max 64 bytes as Modbus Plus Global Data)

Mech Rating: IP20/Nema1

Power supply connector: 2-pole 5.08 mm Phoenix pluggable screw connector

DeviceNet baudrate: 125-500 kbit/s

DeviceNet MacID: 0-63

DeviceNet connector: 5-pole 5.08 mm Phoenix pluggable screw connector

Modbus Plus baudrate: 1 Mbit/s

Modbus Plus address: Node-ID and Source-ID 1-64

ModbusPlus connector: D-sub 9-pin female

Accessory order: 018021 (NetTool-DN configuration tool for DeviceNet)

Price group: C

Order Code: AB7818

 

Reviews

There are no reviews yet.

Be the first to review “DeviceNet Scanner/Master – Modbus Plus Slave”

Your email address will not be published. Required fields are marked *