The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very easy using the windows based configuration software Anybus Configuration Manager X-gateway from HMS (free of charge).

SKU: AB7885

Product Description

The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very easy using the windows based configuration software Anybus Configuration Manager X-gateway from HMS (free of charge).

The Interbus 2Mbit/s interface module is a slave node that can be read from/written to by an Interbus master. Interbus has two ways of exchanging data; one through fast cyclical I/O data called ?Process Data?, and one through a somewhat slower protocol called PCP, which is mainly used for configuration purposes. It supports Interbus PCP V2.0. The module supports up to 10 words of data on the bus, out of which up to four words can be used for PCP. 

The Modbus Plus interface is based on licensed chip-set and software from Modicon Inc. Supporting both the Global Database and Register mapping to 3x and 4x registers this module implements a versatile Modbus Plus interface. The Modbus Plus interface module is certified by the Modconnect and has proven conformance and interoperability with leading PLC´s, HMI´s etc 

 

 

Individually isolated Bus In and Bus Out Interbus interfaces
Up to 10 words of Process data on Interbus
Interbus PCP v2.0 (0, 1, 2 or 4 words)
Modbus Plus Global Data Base Transaction, Point-to-Point commands, Read holding registers, Preset single register
Modbus Plus Host Firmware Rev. 77

Size: 114 mm x 44 mm x 127 mm

Power Supply: 24 VDC (±20%)

Temperature: -25-65°C

Current Consump: max 400 mA

I/O Input: Default 20 bytes, max 512 bytes (max 20 bytes as I/O on Interbus, max 64 bytes as Modbus Plus Global Data)

I/O Output: Default 20 bytes, max 512 bytes (max 20 bytes as I/O on Interbus, max 64 bytes as Modbus Plus Global Data)

Mech Rating: IP20/Nema1

Power supply connector: 2-pole 5.08 mm Phoenix pluggable screw connector

Interbus Baudrate: 500Kbit/s or 2Mbit/s

Interbus connectors: D-sub 9-pin ? Bus In male, Bus Out female

Modbus Plus baudrate: 1 Mbit/s

Modbus Plus address: Node-ID and Source-ID 1-64

ModbusPlus connector: D-sub 9-pin female

Price Group: C

Order Code: AB7885