Profibus Slave – CC Link Slave

£430.00 ex. VAT

The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very easy using the windows based configuration software Anybus Configuration Manager X-gateway from HMS (free of charge).

SKU: AB7852

Product Description

The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very easy using the windows based configuration software Anybus Configuration Manager X-gateway from HMS (free of charge).

The Profibus DP/DPV1 slave interface is implemented according to the standard IEC61158 as a modular slave, supporting all standard functionality such as Watchdog, Sync and Freeze and diagnostics. Including I&M functions. Standard DP as well as DPV1 acyclic data services (Class1/Class2) are supported. The Profibus interface module is certified by the Profibus user organization and has proven conformance and interoperability with leading PLC´s, HMI´s etc. Profibus address is set via rotary switches 0-99.

The CC-Link interface is a slave module for the CC-Link fieldbus system. It contains all the functionality needed to turn an application into a complete CC-Link remote device and it is configured to use the generic PLC profile. The CC-Link interface module is certified by the CLPA organisation and has proven conformance and interoperability with leading PLC´s, HMI´s etc 

 

 

Watchdog support
Sync and Freeze
Supports PA baud rate 45.45 kbit/s
Uses up to 4 occupied stations on CC-Link – configurable size
Uses the CC-Link PLC profile for data exchange
Complete Profibus DP and DPV1 (Class1/Class2) slave functionality according to IEC 61158
Support for CC-Link version 2.0 with extended data

Size: 114 mm x 44 mm x 127 mm

Power Supply: 24 VDC (±20%)

Temperature: -25-65°C

Current Consump: max 400 mA at 24V

I/O Input: Default 20 bytes, CC-Link V.2: max. 244 bytes (max 896 I/O-points and 128 words) CC-Link V.1: max 48 bytes (max 128 I/O-points and 16 words)

I/O Output: Default 20 bytes, CC-Link V.2: max. 244 bytes (max 896 I/O-points and 128 words) CC-Link V.1: max 48 bytes (max 128 I/O-points and 16 words)

Mech Rating: IP20/Nema1

Power supply connector: 2-pole 5.08 mm Phoenix pluggable screw connector

Profibus baudrate: 9600 bit/s – 12 Mbit/s autodetect

Profibus address: Node address 0-99

Profibus connector: D-sub 9-pin female

Profibus config.: Configured by Profibus Master via GSD file (provided by HMS)

CC-Link baudrate: 156kbps to 10Mbps

CC-Link address: Station 1-64

CC-Link connector: 5-pole 5.08 mm Phoenix pluggable screw connector

CC-Link config.: Configured by CC Link Master via CSP Config file (provided by HMS)

Price Group: A

Order Code: AB7852