Products – Adaptive Wireless https://www.adaptive-wireless.co.uk Wireless sensing solutions Fri, 05 Feb 2016 10:30:06 +0000 en-US hourly 1 https://wordpress.org/?v=4.4.2 AS-Interface Master – Ethernet/IP Adapter/Slave Industrial Network Gateway https://www.adaptive-wireless.co.uk/product/as-interface-master-ethernetip-adapterslave/ https://www.adaptive-wireless.co.uk/product/as-interface-master-ethernetip-adapterslave/#respond Thu, 31 Jul 2014 09:44:53 +0000 https://www.adaptive-wireless.co.uk/?post_type=product&p=4500 The Anybus  AS-Interface Master - Ethernet/IP Adapter/Slave Industrial Network Gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very easy using the windows based configuration software Anybus Configuration Manager X-gateway from HMS (free of charge). Continue reading ]]> The Anybus AS-Interface Master – Ethernet/IP Adapter/Slave Industrial Network Gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very easy using the windows based configuration software Anybus Configuration Manager X-gateway from HMS (free of charge).

The Anybus OPC Server is supported and included with this X-gateway. It enables fast and dynamic transfer of fieldbus data to and from e.g. SCADA/HMI/Enterprice level systems based on Microsoft Windows. 

The AS-Interface Master for the Anybus X-gateway implements an extended AS-Interface master (M4), and complies to version 3.0 of the AS-I Complete Specification.
It supports up to 62 slaves with a maximum of 248 digital input and 186 output signals. It also supports 124 analog values. All standard services are available including detailed diagnostics. The network interface is optically isolated and equipped with a 2-pin pluggable screw connector. The Master supports intelligent auto-configuration via the on-board configuration button or manual configuration via a terminal program such as Hyper Terminal for Windows. 
The AS-interface module is certified by the AS Interface user organization and has proven conformance and interoperability with leading manufacturers of I/O, sensors, valves etc.

The EtherNet/IP interface consists of an embedded 2-port Ethernet/IP 10/100 Mbit/s interface with IT functionality such as WEB-server, SSI-scripts, Flash file system, FTP-server, Email client, Telnet etc. It is possible to build web pages displaying and controlling a factory floor process with data from the other connected network. The EtherNet/IP interface module is certified by the ODVA and has proven conformance and interoperability with leading PLC´s, HMI´s etc. The dual port Ethernet interface will allow daisy chaning and removes the need for any external switch. 

KEY FEATURES

Manages control of up to 62 AS-Interface slaves
248 digital inputs and 186 digital outputs
Intelligent auto configuration support
Ethernet 10/100 Mbit/s twisted pair RJ45 connection
TCP/IP settings configurable with web-page, Configuration Tool, DHCP, ARP or with DIP switches
Ethernet/IP level 2 I/O Server CIP (ControlNet & DeviceNet)
1.4 Mbyte storage space on Flash disk
Support for AnyBus IPconfig utility for easy TCP/IP set up
SSI scripts used for easy display/control of process data on webpages
Gateway diagnostics via WEB-pages
Supporting AS-Interface version 3.0
Support for Anybus OPC Server

 

TECHNICAL SPECIFICATIONS

Size: 114 mm x 44 mm x 127 mm

Power Supply: 24 VDC (±20%)

Temperature: -25-65°C

Current Consump: Max 400mA at 24VDC

I/O Input: Default 20 bytes, max 64 bytes (248 digital inputs)

I/O Output: Default 20 bytes, max 64 bytes (186 digital outputs)

Mech Rating: IP20/Nema1

Power supply connector: 2-pole 5.08 mm Phoenix pluggable screw connector

AS-I baudrate: 167 kbit/s

AS-I connector: 2 x 2-pole 5.08 mm Phoenix pluggable screw connectors

Ethernet/IP baudrate: 10/100 Mbit/s autodetect

Ethernet connector: RJ45

Ethernet/IP address: Any valid IP-address

Ethernet/IP config.: Configured by EtherNet/IP Scanner via EDS file (provided by HMS)

Price Group: B

Order Code: AB7820

 

]]>
https://www.adaptive-wireless.co.uk/product/as-interface-master-ethernetip-adapterslave/feed/ 0
AS-Interface Master – Interbus Slave Fo https://www.adaptive-wireless.co.uk/product/as-interface-master-interbus-slave-fo/ https://www.adaptive-wireless.co.uk/product/as-interface-master-interbus-slave-fo/#respond Thu, 31 Jul 2014 09:52:56 +0000 https://www.adaptive-wireless.co.uk/?post_type=product&p=4738 The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very easy using the windows based configuration software Anybus Configuration Manager X-gateway from HMS (free of charge). Continue reading ]]> The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very easy using the windows based configuration software Anybus Configuration Manager X-gateway from HMS (free of charge).

The AS-Interface Master for the Anybus X-gateway implements an extended AS-Interface master (M4), and complies to version 3.0 of the AS-I Complete Specification.
It supports up to 62 slaves with a maximum of 248 digital input and 186 output signals. It also supports 124 analog values. All standard services are available including detailed diagnostics. The network interface is optically isolated and equipped with a 2-pin pluggable screw connector. The Master supports intelligent auto-configuration via the on-board configuration button or manual configuration via a terminal program such as Hyper Terminal for Windows. 
The AS-interface module is certified by the AS Interface user organization and has proven conformance and interoperability with leading manufacturers of I/O, sensors, valves etc.

The Interbus 2MBit/s interface with a Fiber Optic bus-interface is an important complement to the standard module for copper based cabling. The Fiber Optic module is based on the OPC chipset from Pheonix, which gives support for optical diagnostics. This means the unit has a high EMC immunity and also a very low EMC emission. The Interbus interface 2Mbit/s module is a slave node that can be read from/written to by an Interbus master. Interbus has two ways of exchanging data; one through fast cyclical I/O data called ?Process Data?, and one through a somewhat slower protocol called PCP, which is mainly used for configuration purposes. It supports Interbus PCP V2.0. The module supports up to 10 words of data on the bus, out of which up to four words can be used for PCP. 

KEY FEATURES

Manages control of up to 62 AS-Interface slaves
248 digital inputs and 186 digital outputs
Intelligent auto configuration support
Up to 10 words of Interbus Process data
PCP v2.0 (0, 1, 2 or 4 words)
Fibre Optic features FSMA standard connectors conforming to IEC874-2 and DIN47258
Based on OPC chipset with support for optical diagnostics
Transmission Media: Plastic fibre, core 180um, clad 1000um: HCS (glass) fibre, core 200um, clad 230 um
Supporting AS-Interface version 3.0

 

TECHNICAL SPECIFICATIONS

 

Size: 114 mm x 44 mm x 127 mm

Power Supply: 24 VDC (±20%)

Temperature: -25-65°C

Current Consump: max 400 mA

I/O Input: Default 20 bytes, max 64 bytes (248 digital inputs on ASI, max 20 bytes as I/O on Interbus)

I/O Output: Default 20 bytes, max 64 bytes (186 digital outputs on ASI, max 20 bytes as I/O on Interbus)

Mech Rating: IP20/Nema1

Power supply connector: 2-pole 5.08 mm Phoenix pluggable screw connector

AS-I baudrate: 167 kbit/s

AS-I connector: 2 x 2-pole 5.08 mm Phoenix pluggable screw connectors

Interbus Baudrate: 500Kbit/s or 2Mbit/s

Interbus connectors: HFBR-2505C and HFBR-1505C

Price Group: C

Order Code: AB7826

 

]]>
https://www.adaptive-wireless.co.uk/product/as-interface-master-interbus-slave-fo/feed/ 0
AS-Interface Master – ModbusTCP Slave/Server Industrial Network Gateway https://www.adaptive-wireless.co.uk/product/as-interface-master-modbustcp-slaveserver/ https://www.adaptive-wireless.co.uk/product/as-interface-master-modbustcp-slaveserver/#respond Thu, 31 Jul 2014 10:01:18 +0000 https://www.adaptive-wireless.co.uk/?post_type=product&p=4524 The AS-Interface Master - ModbusTCP Slave/Server Industrial Network Gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very easy using the windows based configuration software Anybus Configuration Manager X-gateway from HMS (free of charge). Continue reading ]]> The AS-Interface Master – ModbusTCP Slave/Server Industrial Network Gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very easy using the windows based configuration software Anybus Configuration Manager X-gateway from HMS (free of charge).

The Anybus OPC Server is supported and included with this X-gateway. It enables fast and dynamic transfer of fieldbus data to and from e.g. SCADA/HMI/Enterprice level systems based on Microsoft Windows. 

The AS-Interface Master for the Anybus X-gateway implements an extended AS-Interface master (M4), and complies to version 3.0 of the AS-I Complete Specification.
It supports up to 62 slaves with a maximum of 248 digital input and 186 output signals. It also supports 124 analog values. All standard services are available including detailed diagnostics. The network interface is optically isolated and equipped with a 2-pin pluggable screw connector. The Master supports intelligent auto-configuration via the on-board configuration button or manual configuration via a terminal program such as Hyper Terminal for Windows. 
The AS-interface module is certified by the AS Interface user organization and has proven conformance and interoperability with leading manufacturers of I/O, sensors, valves etc.

The Modbus-TCP interface consists of an embedded ModbusTCP 10/100 Mbit/s 2-port Ethernet interface with IT functionality such as WEB-server, SSI-scripts, Flash file system, FTP-server, Email client, Telnet etc. It is possible to build web pages displaying and controlling a factory floor process with data from the other connected network. The EtherNet/ModbusTCP interface module is certified by the Univeristy of Michigan and has proven conformance and interoperability with leading PLC´s, HMI´s etc. The 2-port Ethernet interface will allow daisy chaining thus removes the need for any external switch. 

KEY FEATURES

Manages control of up to 62 AS-Interface slaves
248 digital inputs and 186 digital outputs
Intelligent auto configuration support
10/100 MBit twisted pair RJ45 connection
TCP/IP settings configurable with web-page, Configuration Tool, DHCP, ARP or with DIP switches
Modbus/TCP class 0, class 1 and partially class 2 slave functionality
1.4 Mbyte storage space on Flash disk
Support for AnyBus IPconfig utility for easy TCP/IP set up
SSI scripts used for easy display/control of process data on WEB-pages
Gateway diagnostics via WEB-pages
Supporting AS-Interface version 3.0
Support for Anybus OPC Server

 

TECHNICAL SPECIFICATIONS

 Size: 114 mm x 44 mm x 127 mm

Power Supply: 24 VDC (±20%)

Temperature: -25-65°C

Current Consump: Max 400mA at 24VDC

I/O Input: Default 20 bytes, max 64 bytes (248 digital inputs on ASI)

I/O Output: Default 20 bytes, max 64 bytes (186 digital outputs on ASI)

Mech Rating: IP20/Nema1

Power supply connector: 2-pole 5.08 mm Phoenix pluggable screw connector

AS-I baudrate: 167 kbit/s

AS-I connector: 2 x 2-pole 5.08 mm Phoenix pluggable screw connectors

Modbus-TCP baudrate: 10/100 Mbit/s autodetect

Modbus-TCP connector: RJ45

Modbus-TCP address: Any valid IP-address

Price Group: B

Order Code: AB7631

 

]]>
https://www.adaptive-wireless.co.uk/product/as-interface-master-modbustcp-slaveserver/feed/ 0
CANopen Master – CANopen Slave https://www.adaptive-wireless.co.uk/product/canopen-master-canopen-slave/ https://www.adaptive-wireless.co.uk/product/canopen-master-canopen-slave/#respond Sun, 03 Aug 2014 13:51:22 +0000 https://www.adaptive-wireless.co.uk/?post_type=product&p=4628 The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 16 bytes Input and 16 bytes Output, two bytes in each direction is used for the Control word and the Status word. Changing default settings is very simple by changing the Fieldbus parameters from the CANopen configuration tool. An external CANopen configuration tool is used to configure the nodes on the CANopen network. The resulting Concise DCF file is downloaded to the CANopen network master using a CANopen adapter. Embedded into a small plastic housing, the CANopen X-gateway is a slim device for standard DIN rail mounting. Continue reading ]]> The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 16 bytes Input and 16 bytes Output, two bytes in each direction is used for the Control word and the Status word. Changing default settings is very simple by changing the Fieldbus parameters from the CANopen configuration tool. An external CANopen configuration tool is used to configure the nodes on the CANopen network. The resulting Concise DCF file is downloaded to the CANopen network master using a CANopen adapter. Embedded into a small plastic housing, the CANopen X-gateway is a slim device for standard DIN rail mounting.

The CANopen master (manager) can connect up to 126 slaves and complies with the CANopen communication profile DS301 v4.0.2. The X-gateway supports the different CANopen functionalities as Heartbeat, Nodeguarding, Sync and Emcy. 128 Receive and 128 Transmit PDOs are available to be used, each PDO can transfer up to 8 bytes.

The X-gateway CANopen can be configurared with the “Anybus Configuration Manager CANopen” which is included in the price of the X-gateway and can be downloaded from www.anybus.com.

The CANopen interface is an adapter class product allowing fast data exchange. The CANopen slaves data map consists of Process Data Objects (fast data) and Service Data Objects (slow data). The data on the CANopen bus is updated when a change is made or on request from another node. The CANopen interface module is certified by the Can In Automation organisation and has proven conformance and interoperability with leading PLC´s, SoftPLC´s, HMI´s etc 

KEY FEATURES

CANopen implementation according to the CANopen specification DS301 v4.0.2.
Network Management (NMT) messages, to configure and initialize the network.
Supporting 128 Receive PDOs and 128 Transmit PDOs, each can transfer up to 8 bytes.
PDO message types: COS (Change of State), Cyclic Synchronous, Acyclic Synchronous.
Synchronization Object (SYNC) is used for synchronizing PDO communication.
Heartbeat Mechanism to monitor the status of nodes.
Node Guarding/Life Guarding Protocol provides possibility to guard slaves or the master.
EMCY (Emergency Object) is used for error reporting.
LSS master functionality.
Slim housing with standard DIN rail mounting.
CANopen slave supports Hearbeat and Node guarding
CANopen profile DS-301 v4.0.2
CANopen slave PDO and SDO data objects supported
CANopen slave supports up to 80 PDOs in each direction
CANopen Master configuration using the included Anybus Configuration Manager CANopen.

 

TECHNICAL SPECIFICATIONS

 

Size: 120 mm x 75 mm x 27 mm

Power Supply: 24 VDC

Temperature: -25-55°C

Current Consump: max 150 mA

Baud Rate: 20 kbit/s – 1 Mbit/s, Auto baud rate detection

I/O Input: 510 bytes

I/O Output: 510 bytes

Config Method: Anybus Configuration Manager – CANopen

Certification: Certified by CAN in Automation (CIA)

CANopen Connector: D-sub 9-pin female

CANopen address: 1-99

CANopen baud rate: 10 kbit/sec-1 Mbit/s

USB-CAN adapter: 021670 (order code for USB to CAN adapter incl. CD with ACM software and manuals)

Order Code: AB7304

 

]]>
https://www.adaptive-wireless.co.uk/product/canopen-master-canopen-slave/feed/ 0
CANopen Slave – CANopen Slave https://www.adaptive-wireless.co.uk/product/canopen-slave-canopen-slave/ https://www.adaptive-wireless.co.uk/product/canopen-slave-canopen-slave/#respond Sat, 02 Aug 2014 08:35:05 +0000 https://www.adaptive-wireless.co.uk/?post_type=product&p=4636 The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very easy using the windows based configuration software Anybus Configuration Manager X-gateway from HMS (free of charge). Continue reading ]]> The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very easy using the windows based configuration software Anybus Configuration Manager X-gateway from HMS (free of charge).

The gateway consits of two independent CANopen interfaces, logically and galvanically separated from each other.

Each of the two CANopen interfaces are adapter class products allowing fast data exchange. The CANopen slave?s data map consists of Process Data Objects (fast data) and Service Data Objects (slow data). The data on the CANopen bus is updated when a change is made or on request from another node. The CANopen interface module is certified by the Can In Automation organisation and has proven conformance and interoperability with leading PLC´s, SoftPLC´s, HMI´s etc 

KEY FEATURES

CANopen PDO and SDO data objects supported
CANopen Unscheduled data exchange support
CANopen profile DS-301 v.4.02
Customizable PDO-mapping
Heatbeat and node guarding support
Network Stor/Restore functionality

 

TECHNICAL SPECIFICATIONS

 

Size: 114 mm x 44 mm x 127 mm

Power Supply: 24 VDC (±20%)

Temperature: -25-65°C

Current Consump: max 400 mA

Baud Rate: 10 kbit/s to 1 Mbit/s

I/O Input: Default 20 bytes, max 512 bytes

I/O Output: Default 20 bytes, max 512 bytes

Mech Rating: IP20/Nema1

Power supply connector: 2-pole 5.08 mm Phoenix pluggable screw connector

CANopen connectors: D-sub 9-pin male

CANopen address: Node address 1-99

CANopen config.: Configured by CanOpen Master via EDS file (provided by HMS)

Price Group: A

Order Code: AB7894

 

]]>
https://www.adaptive-wireless.co.uk/product/canopen-slave-canopen-slave/feed/ 0
CANopen Slave – CC Link Slave https://www.adaptive-wireless.co.uk/product/canopen-slave-cc-link-slave/ https://www.adaptive-wireless.co.uk/product/canopen-slave-cc-link-slave/#respond Sun, 03 Aug 2014 06:30:40 +0000 https://www.adaptive-wireless.co.uk/?post_type=product&p=4637 The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very easy using the windows based configuration software Anybus Configuration Manager X-gateway from HMS (free of charge). Continue reading ]]> The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very easy using the windows based configuration software Anybus Configuration Manager X-gateway from HMS (free of charge).

The CANopen interface is an adapter class product allowing fast data exchange. The CANopen slave?s data map consists of Process Data Objects (fast data) and Service Data Objects (slow data). The data on the CANopen bus is updated when a change is made or on request from another node. The CANopen interface module is certified by the Can In Automation organisation (CANopen conformance: CIA DS-301 V3.0) and has proven conformance and interoperability with leading PLC´s, SoftPLC´s, HMI´s etc 

The CC-Link interface is a slave module for the CC-Link fieldbus system. It contains all the functionality needed to turn an application into a complete CC-Link remote device and it is configured to use the generic PLC profile. The CC-Link interface module is certified by the CLPA organisation and has proven conformance and interoperability with leading PLC´s, HMI´s etc 

KEY FEATURES

CANopen PDO and SDO data objects supported
CANopen Unscheduled data exchange support
CANopen Watch-dog timer
CANopen profile DS-301
Uses up to 4 occupied stations on CC-Link – configurable size
Uses the CC-Link PLC profile for data exchange
Support for CC-Link version 2.0 with extended data

 

TECHNICAL SPECIFICATIONS

 

Size: 114 mm x 44 mm x 127 mm

Power Supply: 24 VDC (±20%)

Temperature: -25-65°C

Current Consump: max 400 mA

I/O Input: Default 20 bytes, CC-Link V.2: max. 368 bytes (max 896 I/O-points and 128 words) CC-Link V.1: max 48 bytes (max 128 I/O-points and 16 words)

I/O Output: Default 20 bytes, CC-Link V.2: max. 368 bytes (max 896 I/O-points and 128 words) CC-Link V.1: max 48 bytes (max 128 I/O-points and 16 words)

Mech Rating: IP20/Nema1

Power supply connector: 2-pole 5.08 mm Phoenix pluggable screw connector

CANopen baudrate: 10 kbit/s to 1 Mbit/s

CANopen connector: D-sub 9-pin male

CANopen address: Node address 1-99

CANopen config.: Configured by CanOpen Master via EDS file (provided by HMS)

CC-Link baudrate: 156kbps to 10Mbps

CC-Link address: Station 1-64

CC-Link connector: 5-pole 5.08 mm Phoenix pluggable screw connector

CC-Link config.: Configured by CC Link Master via CSP Config file (provided by HMS)

Price Group: A

Order Code: AB7897

 

]]>
https://www.adaptive-wireless.co.uk/product/canopen-slave-cc-link-slave/feed/ 0
CANopen Slave – CC Link Slave https://www.adaptive-wireless.co.uk/product/canopen-slave-cc-link-slave-2/ https://www.adaptive-wireless.co.uk/product/canopen-slave-cc-link-slave-2/#respond Sun, 03 Aug 2014 06:36:12 +0000 https://www.adaptive-wireless.co.uk/?post_type=product&p=4664 The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very easy using the windows based configuration software Anybus Configuration Manager X-gateway from HMS (free of charge). Continue reading ]]> The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very easy using the windows based configuration software Anybus Configuration Manager X-gateway from HMS (free of charge).

The CANopen interface is an adapter class product allowing fast data exchange. The CANopen slave?s data map consists of Process Data Objects (fast data) and Service Data Objects (slow data). The data on the CANopen bus is updated when a change is made or on request from another node. The CANopen interface module is certified by the Can In Automation organisation (CANopen conformance: CIA DS-301 V3.0) and has proven conformance and interoperability with leading PLC´s, SoftPLC´s, HMI´s etc 

The CC-Link interface is a slave module for the CC-Link fieldbus system. It contains all the functionality needed to turn an application into a complete CC-Link remote device and it is configured to use the generic PLC profile. The CC-Link interface module is certified by the CLPA organisation and has proven conformance and interoperability with leading PLC´s, HMI´s etc 

KEY FEATURES

CANopen PDO and SDO data objects supported
CANopen Unscheduled data exchange support
CANopen Watch-dog timer
CANopen profile DS-301
Uses up to 4 occupied stations on CC-Link – configurable size
Uses the CC-Link PLC profile for data exchange
Support for CC-Link version 2.0 with extended data

 

TECHNICAL SPECIFICATIONS

 

Size: 114 mm x 44 mm x 127 mm

Power Supply: 24 VDC (±20%)

Temperature: -25-65°C

Current Consump: max 400 mA

I/O Input: Default 20 bytes, CC-Link V.2: max. 368 bytes (max 896 I/O-points and 128 words) CC-Link V.1: max 48 bytes (max 128 I/O-points and 16 words)

I/O Output: Default 20 bytes, CC-Link V.2: max. 368 bytes (max 896 I/O-points and 128 words) CC-Link V.1: max 48 bytes (max 128 I/O-points and 16 words)

Mech Rating: IP20/Nema1

Power supply connector: 2-pole 5.08 mm Phoenix pluggable screw connector

CANopen baudrate: 10 kbit/s to 1 Mbit/s

CANopen connector: D-sub 9-pin male

CANopen address: Node address 1-99

CANopen config.: Configured by CanOpen Master via EDS file (provided by HMS)

CC-Link baudrate: 156kbps to 10Mbps

CC-Link address: Station 1-64

CC-Link connector: 5-pole 5.08 mm Phoenix pluggable screw connector

CC-Link config.: Configured by CC Link Master via CSP Config file (provided by HMS)

Price Group: A

Order Code: AB7897

 

]]>
https://www.adaptive-wireless.co.uk/product/canopen-slave-cc-link-slave-2/feed/ 0
CC Link Slave – CC Link Slave https://www.adaptive-wireless.co.uk/product/cc-link-slave-cc-link-slave/ https://www.adaptive-wireless.co.uk/product/cc-link-slave-cc-link-slave/#respond Thu, 31 Jul 2014 10:13:47 +0000 https://www.adaptive-wireless.co.uk/?post_type=product&p=4665 The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very easy using the windows based configuration software Anybus Configuration Manager X-gateway from HMS (free of charge). Continue reading ]]> The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very easy using the windows based configuration software Anybus Configuration Manager X-gateway from HMS (free of charge).

The gateway consists of two independent CC-Link interfaces, logically and galvanically isolated from each other.

Each of the two CC-Link interfaces are slave modules for the CC-Link fieldbus system. It contains all the functionality needed to turn an application into a complete CC-Link remote device and it is configured to use the generic PLC profile. The CC-Link interface module is certified by the CLPA organisation and has proven conformance and interoperability with leading PLC´s, HMI´s etc 

KEY FEATURES

Logically separated CC-Link interfaces
Uses up to 4 occupied stations on CC-Link – configurable size
Uses the CC-Link PLC profile for data exchange
Support for CC-Link version 2.0 with extended data

 

TECHNICAL SPECIFICATIONS

 

Size: 114 mm x 44 mm x 127 mm

Power Supply: 24 VDC (±20%)

Temperature: -25-65°C

Current Consump: max 400 mA

Baud Rate: 156kbps to 10Mbps

I/O Input: Uses the CC-Link PLC profile for data exchange

I/O Output: Uses the CC-Link PLC profile for data exchange

Mech Rating: IP20/Nema1

Power supply connector: 2-pole 5.08 mm Phoenix pluggable screw connector

CC-Link address: Station 1-64

CC-Link connectors: 5-pole 5.08 mm Phoenix pluggable screw connector

CC-Link config.: Configured by CC Link Master via CSP Config file (provided by HMS)

Price Group: A

Order Code: AB7626

 

]]>
https://www.adaptive-wireless.co.uk/product/cc-link-slave-cc-link-slave/feed/ 0
DeviceNet Adapter/Slave – CC Link Slave https://www.adaptive-wireless.co.uk/product/devicenet-adapterslave-cc-link-slave/ https://www.adaptive-wireless.co.uk/product/devicenet-adapterslave-cc-link-slave/#respond Thu, 31 Jul 2014 10:43:01 +0000 https://www.adaptive-wireless.co.uk/?post_type=product&p=4663 The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very easy using the windows based configuration software Anybus Configuration Manager X-gateway from HMS (free of charge). Continue reading ]]> The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very easy using the windows based configuration software Anybus Configuration Manager X-gateway from HMS (free of charge).

The high performance DeviceNet Slave interface provides instant connectivity to the DeviceNet network. The module conforms to DeviceNet 2.0. The DeviceNet interface module is certified by the ODVA and has proven conformance and interoperability with leading PLC´s, HMI´s etc. Baud rate and MAC ID can be set via DIP switches.

The CC-Link interface is a slave module for the CC-Link fieldbus system. It contains all the functionality needed to turn an application into a complete CC-Link remote device and it is configured to use the generic PLC profile. The CC-Link interface module is certified by the CLPA organisation and has proven conformance and interoperability with leading PLC´s, HMI´s etc 

KEY FEATURES

DeviceNet Specification version: Vol 1: 2.0, Vol 2: 2.0
Conformance test version: A-12
I/O Slave messaging: Bit strobe, Polling, Cyclic, COS and Explicit Messaging
Uses up to 4 occupied stations on CC-Link – configurable size
Uses the CC-Link PLC profile for data exchange
Support for CC-Link version 2.0 with extended data

 

TECHNICAL SPECIFICATIONS

 

Size: 114 mm x 44 mm x 127 mm

Power Supply: 24 VDC (±20%)

Temperature: -25-65°C

Current Consump: max 400 mA

I/O Input: Default 20 bytes, CC-Link V.2: max. 368 bytes (max 896 I/O-points and 128 words) CC-Link V.1: max 48 bytes (max 128 I/O-points and 16 words)

I/O Output: Default 20 bytes, CC-Link V.2: max. 368 bytes (max 896 I/O-points and 128 words) CC-Link V.1: max 48 bytes (max 128 I/O-points and 16 words)

Mech Rating: IP20/Nema1

Power supply connector: 2-pole 5.08 mm Phoenix pluggable screw connector

DeviceNet baud rate: 125-500 kbit/s

DeviceNet MacID: 0-63

DeviceNet connector: 5-pole 5.08 mm Phoenix pluggable screw connector

DeviceNet config.: Configured by DeviceNet Scanner via EDS file (provided by HMS)

CC-Link baudrate: 156kbps to 10Mbps

CC-Link address: Station 1-64

CC-Link connector: 5-pole 5.08 mm Phoenix pluggable screw connector

CC-Link config.: Configured by CC Link Master via CSP Config file (provided by HMS)

Price Group: A

Order Code: AB7862

 

]]>
https://www.adaptive-wireless.co.uk/product/devicenet-adapterslave-cc-link-slave/feed/ 0
DeviceNet Adapter/Slave – ControlNet Adapter/Slave https://www.adaptive-wireless.co.uk/product/devicenet-adapterslave-controlnet-adapterslave/ https://www.adaptive-wireless.co.uk/product/devicenet-adapterslave-controlnet-adapterslave/#respond Thu, 31 Jul 2014 10:49:29 +0000 https://www.adaptive-wireless.co.uk/?post_type=product&p=4688 The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very easy using the windows based configuration software Anybus Configuration Manager X-gateway from HMS (free of charge). Continue reading ]]> The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very easy using the windows based configuration software Anybus Configuration Manager X-gateway from HMS (free of charge).

The high performance DeviceNet Slave interface provides instant connectivity to the DeviceNet network. The module conforms to DeviceNet 2.0. The DeviceNet interface module is certified by the ODVA and has proven conformance and interoperability with leading PLC´s, HMI´s etc. Baud rate and MAC ID can be set via DIP switches.

The ControlNet interface is implemented according to the ControlNet international specification for a Communication adapter (profile number 12). A connection to the Anybus-S ControlNet module can be opened from a ControlNet scanner. The size of the connection can be up to 450 bytes in each direction. The ControlNet module can be read or written to by UCMM (Unscheduled) messages from another ControlNet adapter (slave) or scanner (master). The module is equipped with two BNC contacts for connection to ControlNet. If redundant operation is desired, both connectors are used; otherwise either connector A or B is used. The module is also equipped with a NAP (Network access port) for temporary connection of configuration tools. The minimum Network update time, (NUT), of the module is 5ms. The ControlNet interface module is certified by the ODVA and has proven conformance and interoperability with leading PLC´s, HMI´s etc 

KEY FEATURES

DeviceNet Specification version: Vol 1: 2.0, Vol 2: 2.0
Conformance test version: A-12
I/O Slave messaging: Bit strobe, Polling, Cyclic, COS and Explicit Messaging
Multicasts of both inputs and peer-to peer data on ControlNet
ControlNet Media redundancy
ControlNet Specification version: Communications Adapter profile 12

TECHNICAL SPECIFICATIONS

Size: 114 mm x 44 mm x 127 mm

Power Supply: 24 VDC (±20%)

Temperature: -25-65°C

Current Consump: max 400 mA

I/O Input: Default 20 bytes, max 512 bytes (max 450 bytes as I/O on ControlNet)

I/O Output: Default 20 bytes, max 512 bytes (max 450 bytes as I/O on ControlNet)

Mech Rating: IP20/Nema1

Power supply connector: 2-pole 5.08 mm Phoenix pluggable screw connector

DeviceNet baud rate: 125-500 kbit/s

DeviceNet MacID: 0-63

DeviceNet connector: 5-pole 5.08 mm Phoenix pluggable screw connector

DeviceNet config.: Configured by DeviceNet Scanner via EDS file (provided by HMS)

ControlNet baudrate: 5Mbit/s

ControlNet MacID: 1-99

ControlNet connector: Dual BNC coaxial connectors

ControlNet config.: Configured by ControlNet Scanner via EDS file (provided by HMS)

Price Group: C

Order Code: AB7855