CANopen Master – CANopen Slave

£568.00

The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 16 bytes Input and 16 bytes Output, two bytes in each direction is used for the Control word and the Status word. Changing default settings is very simple by changing the Fieldbus parameters from the CANopen configuration tool. An external CANopen configuration tool is used to configure the nodes on the CANopen network. The resulting Concise DCF file is downloaded to the CANopen network master using a CANopen adapter. Embedded into a small plastic housing, the CANopen X-gateway is a slim device for standard DIN rail mounting.

SKU: AB7304

Product Description

The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 16 bytes Input and 16 bytes Output, two bytes in each direction is used for the Control word and the Status word. Changing default settings is very simple by changing the Fieldbus parameters from the CANopen configuration tool. An external CANopen configuration tool is used to configure the nodes on the CANopen network. The resulting Concise DCF file is downloaded to the CANopen network master using a CANopen adapter. Embedded into a small plastic housing, the CANopen X-gateway is a slim device for standard DIN rail mounting.

The CANopen master (manager) can connect up to 126 slaves and complies with the CANopen communication profile DS301 v4.0.2. The X-gateway supports the different CANopen functionalities as Heartbeat, Nodeguarding, Sync and Emcy. 128 Receive and 128 Transmit PDOs are available to be used, each PDO can transfer up to 8 bytes.

The X-gateway CANopen can be configurared with the “Anybus Configuration Manager CANopen” which is included in the price of the X-gateway and can be downloaded from www.anybus.com.

The CANopen interface is an adapter class product allowing fast data exchange. The CANopen slaves data map consists of Process Data Objects (fast data) and Service Data Objects (slow data). The data on the CANopen bus is updated when a change is made or on request from another node. The CANopen interface module is certified by the Can In Automation organisation and has proven conformance and interoperability with leading PLC´s, SoftPLC´s, HMI´s etc 

 

 

CANopen implementation according to the CANopen specification DS301 v4.0.2.
Network Management (NMT) messages, to configure and initialize the network.
Supporting 128 Receive PDOs and 128 Transmit PDOs, each can transfer up to 8 bytes.
PDO message types: COS (Change of State), Cyclic Synchronous, Acyclic Synchronous.
Synchronization Object (SYNC) is used for synchronizing PDO communication.
Heartbeat Mechanism to monitor the status of nodes.
Node Guarding/Life Guarding Protocol provides possibility to guard slaves or the master.
EMCY (Emergency Object) is used for error reporting.
LSS master functionality.
Slim housing with standard DIN rail mounting.
CANopen slave supports Hearbeat and Node guarding
CANopen profile DS-301 v4.0.2
CANopen slave PDO and SDO data objects supported
CANopen slave supports up to 80 PDOs in each direction
CANopen Master configuration using the included Anybus Configuration Manager CANopen.

Size: 120 mm x 75 mm x 27 mm

Power Supply: 24 VDC

Temperature: -25-55°C

Current Consump: max 150 mA

Baud Rate: 20 kbit/s – 1 Mbit/s, Auto baud rate detection

I/O Input: 510 bytes

I/O Output: 510 bytes

Config Method: Anybus Configuration Manager – CANopen

Certification: Certified by CAN in Automation (CIA)

CANopen Connector: D-sub 9-pin female

CANopen address: 1-99

CANopen baud rate: 10 kbit/sec-1 Mbit/s

USB-CAN adapter: 021670 (order code for USB to CAN adapter incl. CD with ACM software and manuals)

Order Code: AB7304