CC Link Slave – EtherCAT Slave

£430.00

The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very easy using the windows based configuration software Anybus Configuration Manager X-gateway from HMS (free of charge).

SKU: AB7694

Product Description

The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very easy using the windows based configuration software Anybus Configuration Manager X-gateway from HMS (free of charge).

The CC-Link interface is a slave module for the CC-Link fieldbus system. It contains all the functionality needed to turn an application into a complete CC-Link remote device and it is configured to use the generic PLC profile. The CC-Link interface module is certified by the CLPA organisation and has proven conformance and interoperability with leading PLC´s, HMI´s etc

The EtherCAT Slave Interface for the Anybus X-gateway implements CANopen over EtherCAT, and exchanges up to 512 bytes of data in each direction. The interface acts as a slave node, which means it can be accessed by an EtherCAT master, but it will not initiate communication by itself.
The module has two RJ45 connectors using 100 Mbit full duplex Ethernet. For configuration a XML-format device despription file is supplied by HMS.

 

 

Uses up to 4 occupied stations on CC-Link – configurable size
Uses the CC-Link PLC profile for data exchange
Support for CC-Link version 2.0 with extended data
EtherCAT interface supports CANopen objects SDOs and PDOs
Up to 512 bytes of cyclic data in each direction (PDO)
to 512 bytes of acyclic data in each direction (SDO)
EtherCAT interface is DS301 v4.02 compliant

 Size: 114 mm x 44 mm x 127 mm

Power Supply: 24 VDC (±20%)

Temperature: -25-65°C

Current Consump: max 400 mA

I/O Input: Default 20 bytes (max 128 I/O-points and 16 words on CC-Link)

I/O Output: Default 20 bytes (max 128 I/O-points and 16 words on CC-Link)

Mech Rating: IP20/Nema1

Power supply connect: 2-pole 5.08 mm Phoenix pluggable screw connector

CC-Link baudrate: 156kbps to 10Mbps

CC-Link address: Station 1-64

CC-Link connector: 5-pole 5.08 mm Phoenix pluggable screw connector

CC-Link config: Configured by CC Link Master via CSP Config file (provided by HMS)

EtherCAT baudrate: 100 Mbit/s

EtherCAT connector: RJ45

EtherCAT config: Configured by EtherCAT Master via XML file (provided by HMS)

Price Group: A

Order Code: AB7694