ControlNet Adapter/Slave – LonWorks

£860.00 ex. VAT

The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very easy using the windows based configuration software Anybus Configuration Manager X-gateway from HMS (free of charge).

SKU: AB7872

Product Description

The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very easy using the windows based configuration software Anybus Configuration Manager X-gateway from HMS (free of charge).

The ControlNet interface is implemented according to the ControlNet international specification for a Communication adapter (profile number 12). A connection to the Anybus-S ControlNet module can be opened from a ControlNet scanner. The size of the connection can be up to 450 bytes in each direction. The ControlNet module can be read or written to by UCMM (Unscheduled) messages from another ControlNet adapter (slave) or scanner (master). The module is equipped with two BNC contacts for connection to ControlNet. If redundant operation is desired, both connectors are used; otherwise either connector A or B is used. The module is also equipped with a NAP (Network access port) for temporary connection of configuration tools. The minimum Network update time, (NUT), of the module is 5ms. The ControlNet interface module is certified by the ODVA and has proven conformance and interoperability with leading PLC´s, HMI´s etc

The LonWorks interface is a high performance interface to LonWorks networks. The interface supports LonMark objects handling. The required network variables on the LonWorks side can be configured and stored in FLASH. It is based on MIP that allows high throughput and a configurable set of up to 256 input and 256 output network variables. The interface can, via the “LWtool” PC-based configuration utility program, link, and convert data between the other network side and devices located on a LonWorks Network. The LonWorks side of the product can be configured for any type of network variable e.g. SNVT’s or UNVT?s.

 

 

Multicasts of both inputs and peer-to peer data on ControlNet
ControlNet Media redundancy
ControlNet Specification version: Communications Adapter profile 12
Special LW Config Software Tool for Network variable Setup
Certification prepared for Lonmark application layer interoperability guidelines V3.2
LonWorks FT-X1 Transceiver

Size: 114 mm x 44 mm x 127 mm

Power Supply: 24 VDC (±20%)

Temperature: -25-65°C

Current Consump: max 400 mA

I/O Input: Default 20 bytes, max 512 bytes (256 network variables on LonWorks, max 450 bytes as I/O on ControlNet)

I/O Output: Default 20 bytes, max 512 bytes (256 network variables on LonWorks, max 450 bytes as I/O on ControlNet)

Mech Rating: IP20/Nema1

Power supply connector: 2-pole 5.08 mm Phoenix pluggable screw connector

ControlNet baudrate: 5Mbit/s

ControlNet MacID: 1-99

ControlNet connector: Dual BNC coaxial connectors

ControlNet config.: Configured by ControlNet Scanner via EDS file (provided by HMS)

LonWorks baudrate: 78 kbit/s

LonWorks Connector: 5-pole 5.08 mm Phoenix pluggable screw connector

Price Group: C

LonWorks config.: Order code: 018640 – (LW Tool ABX for LonWorks interface variable configuration)

Order Code: AB7872

 

Reviews

There are no reviews yet.

Be the first to review “ControlNet Adapter/Slave – LonWorks”

Your email address will not be published. Required fields are marked *