DeviceNet Scanner/Master – Interbus Slave Cu

£860.00 ex. VAT

The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very easy using the windows based configuration software Anybus Configuration Manager X-gateway from HMS (free of charge).

SKU: AB7814

Product Description

The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very easy using the windows based configuration software Anybus Configuration Manager X-gateway from HMS (free of charge).

The DeviceNet Master interface can act both as a Master/Scanner and/or Adapter/Slave. The entire DeviceNet protocol is implemented into the module. The module manages control of up to 63 DeviceNet slaves. Full DeviceNet configuration can be defined and loaded into the Anybus-M module via the HMS configuration software NetTool-DN (included free of charge) or via Rockwell´s RSNetWorx. 

The Interbus 2Mbit/s interface module is a slave node that can be read from/written to by an Interbus master. Interbus has two ways of exchanging data; one through fast cyclical I/O data called ?Process Data?, and one through a somewhat slower protocol called PCP, which is mainly used for configuration purposes. It supports Interbus PCP V2.0. The module supports up to 10 words of data on the bus, out of which up to four words can be used for PCP. 

 

 

Complete DeviceNet 2.0 scanner implementation according to ODVA
DeviceNet Group 2 Client/Server / UCMM support
Manages up to 63 DeviceNet slaves
DeviceNet Configuration via AnyBus NetTool-DN or RSNetworx
DeviceNet Explicit peer to peer messaging, configuration consistency value. I/O Slave messaging: Bit strobe, Polling, Cyclic & Change of State (COS)
Individually isolated Bus In and Bus Out Interbus interfaces
Up to 10 words of Process data on Interbus
Interbus PCP v2.0 (0, 1, 2 or 4 words)

Size: 114 mm x 44 mm x 127 mm

Power Supply: 24 VDC (±20%)

Temperature: -25-65°C

Current Consump: max 400 mA

I/O Input: Default 20 bytes, max 512 bytes (max 20 bytes as I/O on Interbus)

I/O Output: Default 20 bytes, max 512 bytes (max 20 bytes as I/O on Interbus)

Mech Rating: IP20/Nema1

Power supply connector: 2-pole 5.08 mm Phoenix pluggable screw connector

DeviceNet baudrate: 125-500 kbit/s

DeviceNet MacID: 0-63

DeviceNet connector: 5-pole 5.08 mm Phoenix pluggable screw connector

Interbus Baudrate: 500Kbit/s or 2Mbit/s

Interbus connectors: D-sub 9-pin ? Bus In male, Bus Out female

Accessory order: 018021 (NetTool-DN configuration tool for DeviceNet)

Price group: C

Order Code: AB7814

Reviews

There are no reviews yet.

Be the first to review “DeviceNet Scanner/Master – Interbus Slave Cu”